Masonry Support Design: Angles, Fixings and Movement Joints

Masonry support design is the job of carrying the weight of a brick, block or stone outer leaf back to the building frame at the right levels. You do this with angles, brackets or lintel systems, and fix them so the movement the facade will see can happen without cracking anything. Done well, it is a short set of checks and one clean set of details. Done badly, it becomes a site problem when a slab edge turns out to be in the wrong place.

This guide is for engineers, architects and technical coordinators on UK projects. It covers what a support system does, what you need before you start designing, how loads reach the frame, how to detail joints and openings, and where design goes wrong.

Xponexusengineering
xponexusengineering.com
Add Engineering Capacity for Masonry Design
Xponexus embeds civil and structural engineers into UK consultancy workflows for support calculations, drawings, and BIM coordination.

Explore engineering support

TL;DR

  • A masonry support system carries the outer leaf of a framed building, usually at horizontal movement joints, and passes the load into the frame through angles or brackets and their fixings.
  • Start from the frame type, differential movement, cladding type, masonry load and cavity width. Design is only as good as that input.
  • The movement joint must stay clear: the support sits over it, and no fixing or hard material should bridge it.
  • Eurocode 6 and PD 6697 guide the masonry design, and slab-edge detailing has to work for both the support and the cavity barrier.
  • If your team is short of capacity, we can embed engineers to produce review-ready support calculations and drawings.

Table of Contents

What a masonry support system does

On a framed building, the brickwork or stone is not a loadbearing wall. It is a cladding that hangs on the structure. A masonry support system supports brick, block or stone cladding on a framed structure, usually over horizontal movement joints. The same family of products also carries masonry over door and window openings.

Two reasons explain why you need it:

  1. Height limits on unsupported masonry. The outer leaf cannot simply stack up the full height of the building. Guidance for buildings other than the tallest category says the outer leaf should be supported at intervals not exceeding 9m or three storeys, whichever is less. Check the limit that applies to your building type and the manufacturer’s current literature before fixing levels.
  2. Frame and cladding move differently. Concrete frames shorten over time and brickwork tends to expand. If the leaf is built tight between floors, the two fight each other. A horizontal movement joint under each support level lets them move independently.

In practice, “masonry support angle”, “shelf angle” and “brick support” are used loosely for the same idea: a steel member fixed to the frame that carries the leaf above. Continuous angles are common, but individual brackets are used too, for example where brickwork is curved on plan.

Information you need before design starts

Most delays come from missing information, not difficult calculations. Before anyone sizes an angle, gather the following. A manufacturer’s best practice guide asks for plans, sections and elevations, frame and masonry details, cavity width, wind loads if required, opening, movement joint and DPC locations, support levels and the construction programme.

We turn that into a working checklist:

Input Why it matters
Frame type (concrete, steel, timber) Sets the fixing method and the movement you must allow for
Cladding type and thickness Gives the dead load per metre run
Cavity width Drives the eccentricity of the load on the support
Support levels Fixes where movement joints and slab edges meet
Opening positions Changes the load path and can need local brackets or lintels
DPC and cavity barrier positions Must clear the support and not be interrupted by it
Wind load, where needed Affects restraint and fixing demand
Programme Decides when cast-in items must be ordered and placed

The manufacturer’s own summary is short: consider frame type, differential movement, cladding type, masonry load and cavity width. If any of those five is unknown, the design is provisional, and it is better to say so on the drawing than to let it pass as final.

Concrete frames: decide on cast-in items early

On concrete frames, the best time to resolve the fixing is before the slab is poured. Cast-in channels have to be in the formwork and in the right position, so the support level and the slab edge detail must be agreed with the architect and frame designer first. Late changes mean drilled fixings, which are possible but have their own edge distance and reinforcement-clash constraints.

Steel frames: tolerances matter more

On steel frames the fixings are usually bolted to the steelwork, so the question becomes tolerance and access. Frame fabrication and erection tolerances differ from masonry tolerances, which is why adjustment in the support matters. We cover related coordination in our guide to steel frame detailing checks.

How the load gets into the frame

The load path is simple to describe. Masonry weight sits on the angle or bracket, the angle is fixed to the frame, and the frame carries the force down. The detail that catches people out is that the masonry sits out from the fixing line, across the cavity, so the load acts eccentrically and the fixing sees both shear and a tension or moment effect.

The usual arrangement is a stainless steel system fixed to the frame. For concrete, fixings may use cast-in channels and T-bolts or expansion bolts, while steel frames may use setscrews or Steelgrips.

What a competent check covers:

  • The support member itself: bending and shear of the angle or bracket under the masonry line load, and deflection at the toe so that the leaf above does not see a visible droop or open a joint.
  • The fixings: shear, tension from the eccentric load, edge distances and spacing in the parent material.
  • The supporting structure: the slab edge, beam or column has to take the line load and the local effect of the fixing. That includes local punching or edge reinforcement in a concrete slab.
  • The masonry above: whether the leaf can span or arch between bracket positions and what restraint it needs at the top.
  • Durability: material choice for the exposure, and isolation between dissimilar metals.

For the masonry itself, Eurocode 6 (BS EN 1996) and PD 6697 give the design guidance, and PD 6697 covers corbels and overhangs. Where you design a bespoke fabricated angle, the steel and fixings are checked to their own Eurocodes, and the assumptions have to be written on the calculation.

For wall ties and the restraint side of the leaf, see our note on wall tie spacing on site.

Detailing movement joints and openings

Keep the joint clear

The support goes over a horizontal movement joint. A common arrangement has the support sitting directly over the joint, often with compressible filler, and its underside about 2mm above the joint. The aim is that the masonry below can expand up into the joint without pushing on the steel.

Worker inspecting a support above a movement joint

The same principle applies to the wider facade. Professional guidance says movement joints should be properly executed, clear and uninterrupted by fixings or hard material. It also expects designers to specify fixings suited to the structural frame, compatible with movement joint requirements and with no hard bridging across the joint.

Two checks we apply on every drawing:

  • Is there any mortar, debris, rigid insulation or a cavity tray that can bridge the joint?
  • Does a vertical movement joint line up with the support, so that the angle can slide with the panel rather than lock it?

Tolerance and adjustment

No frame is built exactly where the drawing says. Slotted brackets provide adjustment in the fixing, and compressible joints accommodate movement while thermal breaks reduce cold bridging. When you detail, set the adjustment range on the drawing, and make sure the fixing design is valid at the extremes of that range, not just at the nominal position.

Openings

At openings the masonry load concentrates on the lintel or bracket at each side. Check the bearing, how the load from above reaches the lintel, and whether a support level coincides with the head of the opening. Where it does, resolve it once, deliberately, rather than letting two systems meet by accident.

Slab edges, cavity barriers and fire

The slab edge is where several things compete for the same few hundred millimetres: the support, the cavity barrier, the DPC, insulation and the movement joint. One manufacturer’s white paper makes the point that careful slab-edge detailing is needed to keep both the cavity barrier and the masonry support continuous and effective. On higher-risk buildings, those details are scrutinised at the Gateway 2 stage, so the support details need to be drawn clearly and coordinated across disciplines. If you want a wider picture of how masonry trades fit around this work on a project, there is more in these masonry services pages.

For related fire design of the concrete frame the supports are fixed to, see our practical note on concrete fire resistance.

Slab edges, cavity barriers and fire

A worked sequence for a typical framed building

Here is the order we follow on a concrete-framed block with a brick facade.

  1. Confirm the facade strategy with the architect: brick type, bond, cavity width, insulation, and where movement joints are wanted visually.
  2. Set support levels against the storey heights and the maximum unsupported height for the building type.
  3. Collect loads: masonry self-weight per metre run, any additional load such as stone details or soffit brickwork, and wind where relevant.
  4. Select the fixing method for the frame: cast-in channel for concrete if the pour is still ahead, drilled anchors where it is not, bolted or clamped for steel.
  5. Check the support, fixings and slab edge and record every assumption.
  6. Coordinate with the cavity barrier, DPC and thermal break positions in section and in 3D if the project is on BIM.
  7. Issue the calculation and drawings in a form the checker can follow without a phone call.
  8. Review on site at the first bay, before the rest is built.

The sequence is not complicated. The value comes from doing steps 1, 2 and 6 early, because they decide whether the frame designer’s slab edge can host the support at all.

Common mistakes

  • Support levels fixed after the slabs are poured. Cast-in channels are then missing and the fix becomes expensive.
  • Ignoring cavity width in the load check. A wider cavity means a larger lever arm, so the fixing demand rises.
  • Hard bridging of the joint. Mortar droppings, a rigid board or a stray fixing in the movement joint stop it working.
  • Cavity barrier and support designed separately. They meet at the slab edge, and the drawings need to show how.
  • Tolerances left out. If the design only works at the nominal position, it will not work on site.
  • Calculations without stated assumptions. A checker cannot approve what they cannot trace.

If you are also dealing with reinforcement around the slab edge, our Eurocode 2 drawing checklist covers what reviewers look for.

Our perspective

We work with UK consultancies that have a full desk and a facade package that needs doing now. In our experience the facade support is rarely hard engineering. It is a coordination task that lands late, at the same time as everything else, and it often goes to whoever has an hour free.

That is where we think embedded remote support works well. Our engineers work inside your workflow and standards, produce calculations and drawings aligned to UK standards and Eurocodes, and hand back packages designed to be review-ready. You keep the client relationship and the sign-off. We keep the schedule moving. Our approach is designed so that the assumptions, the load path and the fixing checks are written down in a way your checker can follow, which is the thing that actually shortens review time.

We also think the best masonry support design starts with a conversation about the slab edge, not a catalogue. When a structural engineer, a CAD technician and a BIM coordinator look at the same section early, the cast-in items, the cavity barrier and the movement joint stop competing with each other. That is how we aim to work, and it is why we pair calculation with drawing and modelling capacity rather than selling them apart.

— Mohammed

Where we can help

If you have a facade package and not enough hours, we can take on the support calculations, the sketches and the coordination drawings as part of our structural engineering service, with drawing and model production through our CAD and BIM services. We aim to kick off within 48 hours, work under NDA, and keep you in direct control of your client.

Xponexusengineering

To see how an embedded engineer fits into your team, start with our remote engineering support page. You can also read how a small consultancy scaled with us.

FAQ

What is the difference between a shelf angle and a masonry support angle?

In everyday UK use they describe the same idea: a steel angle or bracket fixed to the frame that carries the masonry above it. “Shelf angle” is the more common term in North American and general usage, while “masonry support” is used for proprietary and bespoke systems. The design checks are the same.

Where are masonry supports needed?

They are used on framed buildings to support brick, block or stone cladding, usually at horizontal movement joints, and over openings. For buildings other than the tallest, guidance says to support the outer leaf at intervals of no more than 9m or three storeys, whichever is less. Confirm the limit for your building with current guidance.

What do I need to give a designer?

Plans, sections and elevations, frame and masonry details, cavity width, wind loads if required, the opening, movement joint and DPC locations, support levels and the programme. The more of these you provide at the start, the fewer revisions follow.

Which standards apply to the masonry design?

Eurocode 6 (BS EN 1996) and PD 6697 are the main references for masonry design in the UK. The support steelwork and fixings are checked against their own Eurocode parts and the manufacturer’s data if a proprietary system is used.

Can you design masonry support as overflow capacity for our team?

Yes. We can embed engineers into your workflow to produce calculations, drawings and model coordination for facade supports, with outputs aligned to UK standards and Eurocodes. Use our remote engineering support page to get started.